User Interfaces vacon • 44
Service support: find your nearest Vacon service center at www.vacon.com
4
Given the standard I/O board compilation on the Vacon 100 AC drive, there are 6 digital inputs
available (Slot A terminals 8, 9, 10, 14, 15 and 16). In the programming view, these inputs are
referred to as follows:
In the example Figure 15, the function
External fault close located in menu M3.5.1 as param-
eter P3.5.1.11, is by default given the value
DigIN SlotA.3 (graphical keypad) or dI A.3 (text
keypad). This means that the function
External fault close is now controlled with a digital signal
to digital input DI3 (terminal 10).
This is what is shown in the parameter list.
Assume you need to change the selected input. Instead of DI3 you wish to use DI6 (terminal 16)
on the standard I/O. Do as instructed here:
Figure 16. Programming digital inputs with graphical keypad
Table 17.
Input type
(Graphical keypad)
Input type
(Text keypad)
Slot Input # Explanation
DigIN dI A. 1 Digital input #1 (terminal 8) on board
in Slot A (standard I/O board).
DigIN dI A. 2 Digital input #2 (terminal 9) on board
in Slot A (standard I/O board).
DigIN dI A. 3 Digital input #3 (terminal 10) on
board in Slot A (standard I/O board).
DigIN dI A. 4 Digital input #4 (terminal 14) on
board in Slot A (standard I/O board).
DigIN dI A. 5 Digital input #5 (terminal 15) on
board in Slot A (standard I/O board).
DigIN dI A. 6 Digital input #6 (terminal 16) on
board in Slot A (standard I/O board).
Code Parameter Default ID Description
P3.5.1.11 External fault close DigIN SlotA.3 405
FALSE = OK
TRUE = External fault
OK
OK
9260.emf
BACK
RESET
BACK
RESET