4. To ground the interference-protected cables, peel the cable shield, fold it over itself,
and attach the bunched‑up shield and cable to the grounding rail with a cable clamp.
5. Inside the enclosure, connect the sensor wires according to the wiring diagram.
More Information
‣
Connecting Sensor and Device Cables (page 218)
17.5.4
 Connecting Sensor Cables (Steel Flange)
Make sure that the cable is properly attached to the mast or the sensor
support arm before you start the installation. Otherwise, it may slip and fall down during
the installation.
CAUTION!
To avoid strain on the connector, make sure you connect the cable properly.
Too much strain may cause the cable to fall
o, damage the cable or connector, or make
the cable or connector susceptible to water leakage.
CAUTION!
• Cable cutters
• Cable stripper
AWS310/AWS310-SITE Installation Manual M211584EN-F