MM101 – D-4E HOT MELT UNIT 43
VALCO MELTON S.L.U. Pol. Ind. Agustinos C/G 34 3116 0 ORCOYEN, NAVARRA
TEL: +34 948 321580 Fax: +34 948 326584 melton@melton.es www.valcomelton.com
The System Ready
Temperature is relative
to the temperature
setpoint of each zone.
The system is ready
(and the System Ready
LED illuminates green)
when all zones reach
their respective
temperature setpoints
minus the System Ready
Temperature Offset.
The system ready signal
enables the pump motor.
This prevents the pump
motor from being
activated before the
adhesive in the pump
has softened.
Consult the adhesive
data sheet to find the
softening point
temperature.
The System Ready
Temperature Offset must
be set to at least -5°F (-
C). If it is set too close
to the setpoint (for
example, -1°F), the
pump motor will stop
during momentary drops
in temperature of any
zone until the zone is
again within 1°F of the
setpoint.
The System Ready
Temperature Offset
parameter range is 0°F
to 36°F (0°C to 20°C)
and the default factory
setting is 5°F (3°C).
This parameter can be
accessed in Password
Level 2 or higher (see
Appendix A Password
Levels
).
System Ready
Temperature