Warning! Failure to observe could result in personal injury, death, or
damage to equipment.
When routing low-voltage leads, follow these guidelines:
• Do not route low-voltage leads in the same conduit as wires
carrying a high-current load.
• Do not route low-voltage leads adjacent to, or across wires carrying
a high-current load. If low-voltage leads must cross or run parallel
to wires carrying high current, keep the leads at least 6" (152 mm)
from high-current wires.
• Do not splice or solder leads.
• Trim leads to the required length. Leads should be only as long as
necessary for installation.
• All wiring should be in conduits or wireways.
Warning! Electrical connections should be made only by experienced
service personnel! Failure to observe could result in
personal injury, death, or damage to equipment.
When connecting the supply of electrical power, follow these guidelines:
• Connect the unit to a “clean” supply of electrical power. Use a
dedicated circuit if posible.
Routing Low-
Voltage Leads
Connecting
the Electrical
Power
If a dedicated circuit is not available,
do not connect the unit to a circuit
that supplies high-amperage
equipment— use another circuit such
as a lighting circuit. Otherwise,
equipment may not function properly