MM101 – D-4E HOT MELT UNIT 44
VALCO MELTON S.L.U. Pol. Ind. Agustinos C/G 34 3116 0 ORCOYEN, NAVARRA
TEL: +34 948 321580 Fax: +34 948 326584 melton@melton.es www.valcomelton.com
When the Ready Delay
Time is used, the
System Ready LED will
illuminate a preset time
after all of the zones
reach their respective
temperature setpoints
minus the System Ready
Temperature Offset. This
feature allows the
adhesive in the system
to heat for an additional
period of time before the
pump motor is enabled.
Once the zones have
reached the System
Ready remaining before
the system is ready is
displayed on the status
bar at the bottom of the
screen.
The ready delay range is
1 minute to 120 minutes.
The default factory
setting is ON at 15
minutes.
To prolong the life of the
seal in the pump, this
default time of 15
minutes should not be
reduced.
This parameter can be
accessed in Password
Level 2 or higher (see
Appendix A
Password Levels)