36 D-303222 PowerMaster-10 / PowerMaster-30 Installer's Guide
Enrollment Procedure
Refer to the device information in the device Installation Instructions, open the device and identify the Enroll
Button. For keyfobs and keypads use the AUX '' button. For gas detectors insert the battery.
Full-Enrollment Procedure (Enroll Now)
Press the Enroll button for 2-5 seconds until the LED turns ON and then release the button. The LED will extinguish or
may blink for few more seconds until the enrollment is completed. If enrollment is successfully completed, the
PowerMaster-10 / PowerMaster-30 sounds the "Happy Tune" and the LCD momentarily shows
and then reads the device details – see Step 3 in the chart below.
Pre-Enrollment Procedure (Enter ID.)
Enter the 7-digit ID number printed on the sticker attached to the device and press to confirm. To enroll
a wired sensor into the wired zone use ID: 050-0001 or 050-0002.
To enroll and configure a device, follow the instructions in the following chart (carefully read the "Additional
Information" for each step according to the indicated step references [1] etc. – see table at end of this
section):
Step 1
Step 2
Step 3
Step 4
Step 5
Select "ADD NEW
DEVICE" Option
[1] Enroll the device or
Enter the device ID
[2]
Select a Zone number
[3] Configure zone &
device Parameters
[4]
[5]
Continue
to Part
B.
See
[4]
See Enrollment
& Pre-Enrolment
Procedures above
See
[5]
C. Configuring the Zone Location, Zone Type, Chime option and Device Parameters
1. A Wired sensor is enrolled to the wired zone input using the Pre-Enrollment procedure and ID number
050-0001/050-0002.
2. Keyfob enrolling can be performed also by the user (via USER SETTINGS menu).
3. Wireless detectors can be enrolled in zones 01-30 (PowerMaster-10) / 01-64 (PowerMaster-30).
4. Because of the high security encryption used, PowerG devices (including Keyfobs) cannot be used on
more than one system.
5. Wired magnetic contact or any other contact can be enrolled in any one zone in PowerMaster-10 and
any two zones in PowerMaster-30.
6. Carefully read the "Additional Information" for each step according to the indicated step references
[1]
etc. – see table at end of this section.
1. A list of factory defaults is printed in APPENDIX G. Default and Programmed Zone Definitions. You may
fill out the blank columns even before you start and proceed to program according to your own list.
2. Steps 6 to 12 are applicable to sensors only.
Z10:SET CHIME
ENTR ID:XXX-XXXX
ENROLL NOW or
EXIT Enrollment
MODIFY Same Dev.
NEXT Device
Z10:DEV SETTINGS
Z10:ZONE TYPE
Z10:LOCATION
ADD NEW DEVICE
ID No. 120-1254
Z05:Motion
Sens
ID No. 120-1254
Z01:Motion
Sens
02:ZONES/DEVICES
DEVICE ENROLLED