68 D-303222 PowerMaster-10 / PowerMaster-30 Installer's Guide
Determine to activate the PGM output during the Exit and Entry delays.
Option settings: disabled (default); turn ON; turn OFF; activate PULSE. [1]
Determine to activate the PGM output upon pressing the AUX () button of keyfob
transmitters that have been configured to activate the PGM output. For further details,
refer to the configuration instructions of the AUX () button of the respective keyfobs'
datasheets.
Option settings: disabled (default); turn ON; turn OFF; activate PULSE; toggle
[1]
Determine to activate the PGM output upon activation of any one of up to 3 sensors
(zones) in the systems irrespective whether the system is armed or disarmed.
To configure:
Press to enter the sub menu and then select the Zone you
wish to program, for example "Zone A". If the zone was configured before, the
display shows the current zone number (Z:xx) and if not, the zone number will be
blank (Z:_ _). To configure the zone number press for the programming cursor
to appear under the first digit. Enter the Zone number (2 digits) you wish to activate
the PGM output and press to confirm. If you wish to add another sensor, select
any of the other two options ("Zone B" and "Zone C") and repeat the above process.
When done press to return.
Option settings: disabled (default); turn ON; turn OFF; activate PULSE;
toggle [1]
Note: If you select toggle, the PGM output will be turned on upon event occurrence
in any of these zones and will be turned off upon next event occurrence, alternately.
Determine to activate the PGM output following failure of the PSTN line
Option settings: by line fail NO (default); by line failYES.
Enter daytime limits between which PGM lighting devices controlled by sensors will
be off, even when the associated sensors are triggered.
Option settings: disabled (default); turn ON; turn OFF; activate PULSE
Determine the PGM output pulse time. This value is the same for all events (by ARM
AWAY, by ARM HOME, by DISARM etc.) which were selected with "activate PULSE"
option.
PGM: BY DELAY
PGM: BY KEYFOB
PGM: BY SENSOR
Zone A Z:_ _
Zone B Z:_ _
Zone C Z:_ _
PGM: BY SENSOR
PGM:BY LINE FAIL
Line fail NO
Line fail YES
PGM: LOCKOUT TIME
start HH:MM A
stop HH:MM A
PGM: PULSE TIME
pulse time 2s
pulse time 30s
pulse time 2m
pulse time 4m