166
Mobile Generator
General Maintenance
16.7 Checking and Draining the Containment System
When
Check and drain the containment system every 50 hours.
Overview
Certain machines are equipped with a containment system. The containment
system protects the environment by collecting fluid leaks (fuel, coolant, or oil)
which might otherwise contaminate the soil.
NOTICE: It is important to check the containment system regularly. A large amount
of fluid collected in a 24-hour period indicates a significant leak.
Requirements
Machine stopped and engine is cool to the touch
Machine is on a level surface
Plastic cloth and a container of sufficient volume to collect drained fluid
Note: Collect, store, and dispose of drained fluid in accordance with current
environmental protection regulations.
Procedure
Perform the procedure below to check and drain the containment system.
1. Open the access door on the side of the machine.
2. Check the fluid level in the containment system.
3. If fluid has accumulated, drain the containment system.
a.Place a plastic cloth and a collection container beneath the machine.
b.Remove the drain plug (a). Drain accumulated fluid into a suitable container.
c. Apply pipe sealant to the drain plug.
d.Re-install the drain plug.
Result
The containment system has now been checked and drained.
wc_gr012332