7.6 Diesel Particulate Filter (DPF)
Overview
The machine may be equipped with a Diesel Particulate Filter (DPF). The DPF (a)
helps to protect the environment by removing soot from the engine exhaust.
Function
Sustained operation of the generator under load heats the DPF to a temperature
high enough to burn accumulated soot. As long as a minimum internal temperature
is maintained, this process (“passive regeneration”) will occur automatically.
Passive regeneration is controlled by the Electronic Control Unit (ECU) on the
engine.