Watlow EZ-ZONE
®
PMI Controller 115 Chapter 6 Setup Page
Setup Page
Display
Parameter Name
Description
Range Default
Modbus
Relative Ad-
dress
CIP -
Class
Instance
Attribute
hex (dec)
Pro-
fibus
Index
Param-
eter
ID
Data
Type
and
Access
**
sp.LL
SP.LL
Limit (1)
Minimum Set Point
Set the low end of
the limit set point
range.
-1,999.000 to
9,999.000
-1,999.000 Instance 1
Map 1 Map 2
698 738
0x70
(112)
1
0xA (10)
43 12010 float
RWES
Lh.s
Lh.S
Limit (1)
High Limit Set
Point *
Set the high process
value that will trig-
ger the limit.
-1,999.000 to
9,999.000°F or units
-1,128.000 to
5,537.000°C
0.0°F or
units
-18.0°C
Instance 1
Map 1 Map 2
686 726
0x70
(112)
1
4
39 12004 float
RWES
LL.s
LL.S
Limit (1 )
Low Limit Set
Point *
Set the low process
value that will trig-
ger the limit.
-1,999.000 to
9,999.000°F or units
-1,128.000 to
5,537.000°C
0.0°F or
units
-18.0°C
Instance 1
Map 1 Map 2
684 724
0x70
(112)
1
3
38 12003 float
RWES
sfn.a
SFn.A
Limit (1)
Source Function A *
Set the source for
the limit reset func-
tion.
nonE None (61)
dio Digital I/O
(1142)
fUn Function Key
(1001)
None Instance 1
Map 1 Map 2
- - - - 748
0x70
(112)
1
0x0F
(15)
- - - - 12015 uint
RWES
si.a
Si.A
Limit (1)
Source Instance A *
Set the instance of
the function select-
ed above.
1 to 12 1 - - - - 0x70
(112)
1
0x10
(16)
- - - - 12016 uint
RWES
L.Cr
LCr
Limit (1)
Clear Limit *
Clear limit once
limit condition is
safe.
CLr Clear (0)
ignr Ignore (204)
- - - -
Instance 1
Map 1 Map 2
680 720
0x70
(112)
1
1
- - - - 12014 uint
W
L.st
L.St
Limit (1)
Limit Status *
Reflects whether
or not the limit is
in a safe or failed
mode.
faiL Fail (32)
safE Safe (1667)
- - - -
Instance 1
Map 1 Map 2
- - - - 744
0x70
(112)
1
0x0D
(13)
- - - - 12013 uint
R
* These parameters/prompts are available in these menus with firmware revisions 11.0 and above.
** R: Read, W: Write, E: EEPROM, S: User Set