EasyManua.ls Logo

Watlow ez-zone pm - Real Time Clock Menu

Watlow ez-zone pm
256 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Watlow EZ-ZONE
®
PMI Controller 155 Chapter 6 Setup Page
Setup Page
Display
Parameter Name
Description
Range Default
Modbus
Relative Ad-
dress
CIP -
Class
Instance
Attribute
hex (dec)
Pro-
fibus
Index
Param-
eter
ID
Data
Type
and
Access
**
rtC
SEt
Real Time Clock Menu
hoUr
hoUr
Real Time Clock
Hours
Set the current
time.
0 to 23 0 Instance 1
Map 1 Map 2
- - - - 4004
88 (136)
1
3
- - - - 36003 uint
RW
ЛЏin
Min
Real Time Clock
Minutes
Set the current
time.
0 to 59 0 Instance 1
Map 1 Map 2
- - - - 4006
88 (136)
1
4
- - - - 36004 uint
RW
doФІ
doW
Real Time Clock
Day of Week
Set the current day
of the week.
sun Sunday (1565)
ЛЏon Monday (1559)
tuE Tuesday (1560)
ФІEd Wednesday
(1561)
thUr Thursday
(1562)
fri Friday (1563)
sat Saturday (1564)
Sun Instance 1
Map 1 Map 2
- - - - 4002
88 (136)
1
2
- - - - 36002 uint
RW
* These parameters/prompts are available in these menus with firmware revisions 11.0 and above.
** R: Read, W: Write, E: EEPROM, S: User Set

Table of Contents