EasyManua.ls Logo

Watlow ez-zone pm - Current Menu

Watlow ez-zone pm
256 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Watlow EZ-ZONE
®
PMI Controller 83 Chapter 5 Operations Page
Operations Page
Display
Parameter Name
Description
Range Default
Modbus
Relative Ad-
dress
CIP
Class
Instance
Attribute
hex (dec)
Pro-
fibus
Index
Pa-
ram-
eter
ID
Data
Type
and
Ac-
cess
**
A.st
A.St
Alarm (1 to 4)
State
Current state of
alarm
Startup (88)
None (61)
Blocked (12)
Alarm low (8)
Alarm high (7)
Error (28)
- - - - Instance 1
Map 1 Map 2
1496 1896
Offset to
next instance
(Map1 1
equals +50,
Map 2 equals
+60)
0x6D
(109)
1 to 2
9
- - - -
9009 uint
R
No Dis-
play
Alarm (1 to 4)
Alarm Clearable
Indicates if alarm
can be cleared.
No (59)
Yes (106)
Instance 1
Map 1 Map 2
1502 1902
Offset to
next instance
(Map1 1
equals +50,
Map 2 equals
+60)
0x6D
(109)
1 to 4
0xC (12)
- - - -
9012 uint
R
No Dis-
play
Alarm (1 to 4)
Alarm Silenced
Indicates if alarm is
silenced.
No (59)
Yes (106)
- - - - Instance 1
Map 1 Map 2
1500 1900
Offset to
next instance
(Map1 1
equals +50,
Map 2 equals
+60)
0x6D
(109)
1 to 4
0x0B (11)
- - - -
9011 uint
R
No Dis-
play
Alarm (1 to 4)
Alarm Latched
Indicates if alarm is
latched.
No (59)
Yes (106)
- - - - Instance 1
Map 1 Map 2
1498 1898
Offset to
next instance
(Map1 1
equals +50,
Map 2 equals
+60)
0x6D
(109)
1 to 4
0x0A (10)
- - - -
9010 uint
R
CUrr
opEr
Current Menu
C.hi
C.hi
Current (1)
High Set Point
Set the current val-
ue that will trigger
a high heater error
state.
-1,999.000 to
9,999.000
50.0 Instance 1
Map 1 Map 2
1134 1374
0x73
(115)
1
8
- - - -
15008 float
RWES
** R: Read, W: Write, E: EEPROM, S: User Set