PMI Controller • 163 • Chapter 7 Profiling Page
Profiling Page
Display
Parameter Name
Description
Range Default
Modbus
Relative
Address
CIP
Class
Instance
Attribute
hex (dec)
Pa-
ram-
eter
ID
Data
Type
and
Access
**
ratE
rAtE
Step Type Parameters
Rate
When Step Type is Rate, en-
ter the rate for ramping in
degrees or units per minute.
0 to 9,999.000°F or
units per minute
0 to 5,555.000°C per
minute
0.0 Instance 1
Map 1 Map 2
2580 4510
Offset to
next in-
stance (Map
1 equals
+50, Map 2
equals +100)
0x79 (121)
1 to 40
6
21006 float
RWE
ФІ.Pi
W.Pi
Step Type Parameters
Wait For Process Instance
When Step Type is Wait for
Process or Wait For Both,
enter which analog input
specified by Wait For Process
1 must be met before pro-
ceeding in profile.
1 or 2
1 Instance 1
Map 1 Map 2
2598 4528
Offset to
next in-
stance (Map
1 equals
+50, Map 2
equals +100)
0x79 (121)
1 to 40
0x0F (15)
21015 uint
RWE
ФІ.P1
W.P1
Step Type Parameters
Wait For Process 1
When Step Type is Wait for
Process or Wait For Both,
enter wait for process value
on analog
input specified by Wait For
Process Instance before pro-
ceeding in profile.
-1,999.000 to
9,999.000°F or
units
-1,128.000 to
5,537.000°C
0.0°F or
units
-18.0°C
Instance 1
Map 1 Map 2
2590 4520
Offset to
next in-
stance (Map
1 equals
+50, Map 2
equals +100)
0x79 (121)
1 to 40
0x0B (11)
21011 float
RWE
Note:
Some values will be rounded off to fit in the four-character display. Full values can be read with other inter-
faces.
** R: Read, W: Write, E: EEPROM, S: User Set