8
CFW-10 - QUICK PARAMETER REFERENCE
Software: V2.XX
Application:
Model:
Serial Number:
Responsible:
Date: / / .
QUICK PARAMETER REFERENCE, FAULT AND STATUS MESSAGES
I. Parameters
Parameter Function Adjustable Range
Factory
Unit
User
Page
Setting Setting
P000 Access Parameter 0 to 4, 6 to 999 = Read 0 - 61
5 = Alteration
READ ONLY PARAMETERS - P002 to P099
P002 Fequency Proportional Value 0.0 to 999 - - 61
(P208 x P005)
P003 Motor Current (Output) 0 to 1.5 x I
nom
- A 61
P004 DC Link Voltage 0 to 524 - V 61
P005 Motor Frequency (Output) 0.0 to 99.9, 100 to 300 - Hz 61
P007 Motor Voltage (Output) 0 to 240 - V 61
P008 Heatsink Temperature 25 to 110 - ºC 61
P014 Last Fault 00 to 41 - - 61
P015 Second Fault Occurred 00 to 41 - - 61
P016 Third Fault Occurred 00 to 41 - - 61
P023 Software Version x.yz - - 61
P040 PID Process Variable 0.0 to 999 - - 62
REGULATION PARAMETERS - P100to P199
Ramps
P100 Acceleration Time 0.1 to 999 5.0 s 62
P101 Deceleration Time 0.1 to 999 10.0 s 62
P102 Acceleration Time Ramp 2 0.1 to 999 5.0 s 62
P103 Deceleration Time Ramp 2 0.1 to 999 10.0 s 62
P104 S Ramp 0 = Inactive 0 % 62
1 = 50
2 = 100
Frequency Reference
P120 Digital Reference Backup 0 = Inactive 1 - 63
1 = Active
2 = Backup by P121
3 = Active after Ramp
P121 Keypad Frequency Reference P133 to P134 3.0 Hz 64
P122 JOG Speed Reference P133 to P134 5.0 Hz 64
P124 Multispeed Reference 1 P133 to P134 3.0 Hz 64
P125 Multispeed Reference 2 P133 to P134 10.0 Hz 64
P126 Multispeed Reference 3 P133 to P134 20.0 Hz 64
P127 Multispeed Reference 4 P133 to P134 30.0 Hz 64
P128 Multispeed Reference 5 P133 to P134 40.0 Hz 65
P129 Multispeed Reference 6 P133 to P134 50.0 Hz 65
P130 Multispeed Reference 7 P133 to P134 60.0 Hz 65
P131 Multispeed Reference 8 P133 to P134 66.0 Hz 65
Frequency Limits
P133 Minimum Frequency (F
min
) 0.00 to P134 3.0 Hz 66
P134 Maximum Frequency (F
max
) P133 to 300 66.0 Hz 66