71
DETAILED PARAMETER DESCRIPTION
Read-Only Parameters Variables that can be viewed on the
display, but can not be changed by the
user.
Regulation Parameters Programmable values used by the
CFW-08 functions.
Configuration Parameters They define the inverter characteristics,
the functions to be executed, as well as
the input/output functions of the control
board.
Motor Parameters Data about the applied motor: data
indicated on the motor nameplate and
those obtained during the running of the
self-tuning routine.
Special Function Parameters Here are included parameters related to
special functions, like PID regulator.
Figure 6.3 - Block diagram of the local and remote operation mode
LOCAL
Frequency
Reference
P221
Controls
P229 (stop/run,
FWD/REV and
JOG)
0 Keypad
(HMI-CFW08-P and
HMI-CFW08-RS)
1 AI1
2 or 3 AI2
4EP
5 Serial
6 Multispeed
7 Add AI
8 Add AI>0
0 HMI-CFW08-P
keypad
1 Bornes XC1 (DIs)
2 Serial or HMI-
CFW08-RS keypad
REMOTE
Frequency
Reference
P222
Controls
P230 (start/stop,
FWD/REV and
JOG)
0 Keypad
(HMI-CFW08-P and
HMI-CFW08-RS)
1 AI1
2 or 3 AI2
4EP
5 Serial
6 Multispeed
7 Add AI
8 Add AI>0
0 HMI-CFW08-P
keypad
1 Termin. XC1 (DIs)
2 Serial or
HMI-CFW08-RS
keypad
REFERENCE
COMMANDS
Local/Remote Selection (P220)
+
Local/Remote Command
( , DI, serial, etc)
6.3 PARAMETER
LISTING
In order to simplify the explanation, the parameters have been grouped by
characteristics and functions:
F*

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WEG CFW08 Vector inverter Plus and is the answer not in the manual?

WEG CFW08 Vector inverter Plus Specifications

General IconGeneral
Frequency50/60 Hz
Output Frequency0-400 Hz
Overload Capacity150% for 60 seconds
Protection DegreeIP20
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Short Circuit
BrakingDynamic braking (with optional braking resistor)
Communication InterfaceRS-485 (Modbus RTU)
Ambient Temperature-10°C to +50°C
Humidity5 to 95% non-condensing
Cooling MethodFan Cooled
DimensionsVaries depending on model (refer to specific model datasheet)
Power Range0.75-15 kW
Input Voltage200-240V AC
Storage Temperature-25°C to 65°C (-13°F to 149°F)