Maintenance
Exhaust gas aftertreatment system 9.14
213
[en] | 05/2019 | 1000408123 | 4080T Basic Line | Operator’s Manual
DOC
Fig.207: Position of the diesel oxida-
tion catalyst
If the vehicle is equipped with a diesel oxidation catalyst, the operator
does not have to carry out any work.
Maintenance and repair on the diesel oxidation catalyst may only be per-
formed by an authorized service center.
9.14.3
Safety instructions on diesel particulate filter
WARNING
The exhaust system becomes very hot. There is a risk of burning!
During regeneration, exhaust gas temperatures of approx. 600 °C can oc-
cur in the exhaust system, even when the engine is idling.
Keep your hands clear of the exhaust outlet.
Keep a safe distance from the exhaust system.
Do not open engine cover during regeneration and shortly after.
NOTICE
The exhaust system becomes very hot. There is a risk of fire!
Hot exhaust gases can cause fires in environments with highly flammable
materials and cause significant property damage.
When regenerating the diesel particulate filter, make sure that there
are no easily inflammable materials in the direct vicinity of the ex-
haust system, e.g. paper, dry grass, wood, wooden ceilings, oil,
fuels, etc.
Do not park the vehicle with the engine running in direct proximity to
easily flammable materials.
Do not use corrosion-protection agents for the exhaust system.
These can ignite at the exhaust system.
In environments with easily flammable material, disable the "auto-
matic regeneration" mode.
Do not start "manual regeneration" in environments with flammable
materials.