3064298_201805 53
AMdisplaymodule
24.3 Displays
In the AM "Displays" submenu, the following real-time statuses and measured values, as well as statistical system
data,canberetrieved.Valuesaredisplayedaccordingtosystemtypeandconguration.
Designation Unit Meaning
T_boiler °C Flow temperature
T_boiler set °C Flow temperature (set value)
System pressure bar Secondary pressure/heating circuit pressure
T_outside °C Outside temperature
T_return °C Return temperature
T_return, set °C Return temperature (set value)
T_DHW °C DHW cylinder temperature
T_header °C Header/separating/buffer cylinder temperature
T_header, set °C Header/separating/buffer cylinder temperature (set value)
E1 E1 input status
Fan speed rpm Fan speed (rpm)
ZHP speed % PWM activation of the feed/heating circuit pump (ZHP)
Electric heater status Electric heater status
Add HG status Status of additional heat generator
AWO T_boiler °C Flow temperature (AWO/EWO board temperature sensor)
T_refrigerant (ICT) °C Refrigerant temperature (via AWO/EWO board pressure sensor)
Heatingcircuitowrate l/min Heatingcircuitowrate
Power consumption kW Electrical power consumption
Heating output kW Thermal output in heating/DHW mode
Cooling capacity kW Thermal output in cooling mode
Compressor frequency Hz Compressor speed (rps)
T_evaporator °C Evaporator temperature
T_condenser °C Condenser temperature (AWO/EWO board temperature sensor)
T_hot gas °C Hot gas temperature
T_supply air °C Supply air temperature
Htg energy amount kWh Amount of thermal energy in heating mode
DHW energy amount kWh Amount of thermal energy in DHW mode
Coolg energy amount kWh Amount of thermal energy in cooling mode
Compressor hrs run hrs No. of compressor hours run
Hrs run, boost. htr hrs No. of electric heater hours run
No. of compr starts pce No. of compressor starts
PV status PV input status (PV increase)
Smart grid status SG inputs status (Smart Grid function)
HCM-3rmware HCM-3 PCB software version
24.4 Standardsettings
Inthe"Standardsettings"submenuoftheAM,thefollowingstandardsystemsettingscanbecongured.
Designation Setting range Factory setting
Language German, ... German
Key lock OFF, ON OFF
DHW op mode ECO, Comfort ECO
DHW quick htg OFF, ON OFF
Active cooling OFF, ON OFF
Nightmode→AMFW1.70→contractorparameterWP066 OFF, ON ON