Wolf BWL-1S-07 - System Configuration 11

Wolf BWL-1S-07
120 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3064298_201805 75
Systemcongurations
29.2.4 Systemconguration11
BWL-1S(B)
Splitair/waterheatpump
Separatingcylinder
Oneheatingcircuit
DHWheating
Important information:
In this schematic diagram, shut-off valves, air vent valves and safety equipment are not fully represented.
These should be provided for each system individually, in line with the applicable standards and regulations.
Hydraulic and electrical data can be found in the hydraulic system solutions technical guide.
Separating cylinder
Heating circuit
A 3-way diverter valve for
central heating/DHW and a
feed/heating circuit pump
are integrated into the
indoor module
Indoor module
DHW cylinder
SF
Outdoor module
SAF
HCP
Please note:
Header temperature sensor SAF must be
installed in the return area of the low loss
header or separating cylinder.