Error Troubleshooting
Phaser 6600 and WorkCentre 6605 Xerox Internal Use Only
Service Manual
2-168
117 331 DSP-related
Program Internal
Error
In relation to DSP, the
following internal error has
occurred.
?OS function return value
error
?DSP program load fail
Scanner Controller Error 117-331
Power Off/On the Printer.
If this failure occurs again, please
contact customer support.
Replace the
IP Board.
117 340 HOOK task error Fax Controller Error 117-340
Power Off/On the Printer.
If this failure occurs again, please
contact customer support.
Replace the
IP Board.
117 344 FLASHFILE task error Fax Error 117-344
Power Off/On the Printer.
If this failure occurs again, please
contact customer support.
Replace the
IP Board.
117 350 Task initialization (start)
error
Fax Controller Error 117-350
Power Off/On the Printer.
If this failure occurs again, please
contact customer support.
Replace the
IP Board.
117 361 IIT Parameter
Verify NG
(The IIT
Parameter setting
value is checked
only at the
production
process. )
IIT registration
adjustment value
verification NG.
(Checked only at
production process)
Scanner Parameter Error 117-361
Power Off/On the Printer.
If this failure occurs again, please
contact customer support.
Replace the
IP Board.
117 362 EEPROM Sum
Check Error
EEPROM sumcheck value
error
Fax EEPROM Error 117-362
Power Off/On the Printer.
If this failure occurs again, please
contact customer support.
Replace the
IP Board.
117 363 NVM Sum Check
Error
NVM sumcheck value error Fax NVRAM Error 117-363
Power Off/On the Printer.
If this failure occurs again, please
contact customer support.
Replace the
IP Board.
117 365 Low Voltage RTC detected Low Voltage.
RTC clock setting and
content of SRAM are
invalid. Initialize them.
Controller Clock Voltage Low
Error 117-365
Power Off/On the Printer.
If this failure occurs again, please
contact customer support.
Replace the
IP Board.
WorkCentre 6605 Error Code List
Chain Link Error Error Details Control Panel Messages
FIP
location