Service Parts Disassembly
Xerox Internal Use Only Phaser 6600 and WorkCentre 6605
Service Manual
4-95
Exit Drive Assembly
(PL17.1.21)
WARNING: The Fuser is very hot. Take added care when handling the fuser to avoid being burned.
1. Remove the Transfer Belt Assembly. (page 4-38)
2. Remove the Top Cover Assembly. (SFP page 4-115; MFP page 4-118)
3. Remove the Development HVPS Board. (page 4-99)
4. Remove the IP Board. (SFP page 4-102; MFP page 4-104)
5. Remove the Drive Assembly. (SFP page 4-11; MFP page 4-16)
6. Remove the Exit Assembly. (page 4-93)
7. Unplug connectors P/J38 and P/J40 connected to the MCU Board (PL18.1.13), and release the
harness from the clamp and the harness guide.
8. Unplug the harness from the interim connector on top of the Exit Drive Assembly.