EasyManuals Logo

YASKAWA GA500 Maintenance & Troubleshooting

YASKAWA GA500
292 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #10 background imageLoading...
Page #10 background image
1.1 Section Safety
10 YASKAWA TOEPYAIGA5001A GA500 DRIVE MAINTENANCE & TROUBLESHOOTING
1.1 Section Safety
DANGER
Electrical Shock Hazard
Do not examine, connect, or disconnect wiring on an energized drive. Before servicing, disconnect
all power to the equipment and wait for the time specified on the warning label at a minimum. The
internal capacitor stays charged after the drive is de-energized. The charge indicator LED
extinguishes when the DC bus voltage decreases below 50 Vdc. When all indicators are OFF,
measure for dangerous voltages to make sure that the drive is safe.
If you do work on the drive when it is energized, it will cause serious injury or death from electrical shock.
Disconnect all power to the drive and wait for the time specified on the warning label before you
remove covers. Check the drive for dangerous voltages before servicing or repair work.
If you do work on the drive when it is energized and there is no cover over the electronic circuits, it will cause
serious injury or death from electrical shock. The drive has internal capacitors that stay charged after you de-
energize the drive.
WARNING
Electrical Shock Hazard
The motor will run after you de-energize the drive. PM motors can generate induced voltage to the
terminal of the motor after you de-energize the drive.
If you touch a motor that is moving or energized, it can cause serious injury or death.
Do not operate the drive when covers are missing. Replace covers and shields before you operate
the drive. Use the drive only as specified by the instructions.
Some figures in this section include drives without covers or safety shields to more clearly show the inside of the
drive. If covers or safety shields are missing from the drive, it can cause serious injury or death.
Always ground the motor-side grounding terminal.
If you do not ground the equipment correctly, it can cause serious injury or death if you touch the motor case.
Only let approved personnel install, wire, maintain, examine, replace parts, and repair the drive.
If personnel are not approved, it can cause serious injury or death.
Do not wear loose clothing or jewelry when you do work on the drive. Tighten loose clothing and
remove all metal objects, for example watches or rings.
Loose clothing can catch on the drive and jewelry can conduct electricity and cause serious injury or death.
Fire Hazard
Tighten all terminal screws to the correct tightening torque.
Connections that are too loose or too tight can cause incorrect operation and damage to the drive. Incorrect
connections can also cause death or serious injury from fire.
Damage to Equipment
Do not apply incorrect voltage to the main circuit of the drive. Operate the drive in the specified
range of the input voltage on the drive nameplate.
Voltages that are higher than the permitted nameplate tolerance can cause damage to the drive.
Fire Hazard
Do not put flammable or combustible materials on top of the drive and do not install the drive near
flammable or combustible materials. Attach the drive to metal or other noncombustible material.
Flammable and combustible materials can start a fire and cause serious injury or death.

Table of Contents

Other manuals for YASKAWA GA500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA GA500 and is the answer not in the manual?

YASKAWA GA500 Specifications

General IconGeneral
SeriesGA500
Overload Capacity150% for 60 seconds, 200% for 3 seconds
EnclosureIP20
Control MethodV/f Control
BrakingDynamic Braking
CommunicationEthernet/IP, Modbus RTU, Modbus TCP, DeviceNet, PROFIBUS, PROFINET
SafetySTO (Safe Torque Off)
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheat, Ground Fault, Short Circuit
Humidity95% RH or less (non-condensing)
Output VoltageMatches input voltage
Storage Temperature-25 to +70 °C

Related product manuals