Parameter List
3
3.8 E: Motor Parameters
YASKAWA TOEPYAIGA5001A GA500 DRIVE MAINTENANCE & TROUBLESHOOTING 115
3.8 E: Motor Parameters
◆ E1: V/f Pattern for Motor 1
No.
(Hex.)
Name Description
Default
(Range)
E1-01
(0300)
Input AC Supply Voltage Sets the drive input voltage.
NOTICE: Damage to Equipment. Set E1-01 [Input AC Supply Voltage]
to align with the drive input voltage (not motor voltage). If this parameter
is incorrect, the protective functions of the drive will not operate correctly
and it can cause damage to the drive.
200 V Class: 240 V,
400 V Class: 480 V
(200 V Class: 155 to 255 V,
400 V Class: 310 to 510 V)
E1-03
(0302)
V/f Pattern Selection Sets the V/f pattern for the drive and motor. You can use one of the preset patterns or you can make a
custom pattern.
0 : Const Trq, 50Hz base, 50Hz max
1 : Const Trq, 60Hz base, 60Hz max
2 : Const Trq, 50Hz base, 60Hz max
3 : Const Trq, 60 Hz base, 72 Hz max
4 : VT, 50Hz, 65% Vmid reduction
5 : VT, 50Hz, 50% Vmid reduction
6 : VT, 60 Hz, 65% Vmid reduction
7 : VT, 60 Hz, 50% Vmid reduction
8 : High Trq, 50Hz, 25% Vmin Boost
9 : High Trq, 50Hz, 65% Vmin Boost
A : High Trq, 60 Hz, 25% Vmin Boost
B : High Trq, 60 Hz, 65% Vmin Boost
C : Const Trq, 60 Hz base, 90 Hz max
D : Const Trq, 60 Hz base, 120 Hz max
E : Const Trq, 60 Hz base, 180 Hz max
F : V/f Pattern Selection
Note:
• When A1-02 = 2 [Control Method Selection = OLV], settings 0 to E are not available.
• Set the correct V/f pattern for the application and operation area. An incorrect V/f pattern can
decrease motor torque and increase current from overexcitation.
F
(Determined by A1-02)
E1-04
(0303)
Maximum Output Frequency Sets the maximum output frequency for the V/f pattern. Determined by A1-02 and
E5-01
(Determined by A1-02 and
E5-01)
E1-05
(0304)
Maximum Output Voltage Sets the maximum output voltage for the V/f pattern. 200 V Class: 230.0 V, 400 V:
460.0 V
(200 V Class: 0.0 - 255.0 V,
400 V Class: 0.0 - 510.0 V)
E1-06
(0305)
Base Frequency Sets the base frequency for the V/f pattern. Determined by A1-02 and
E5-01
(0.0 - E1-04)
E1-07
(0306)
Mid Point A Frequency Sets a middle output frequency for the V/f pattern. Determined by A1-02
(0.0 - E1-04)
E1-08
(0307)
Mid Point AVoltage Sets a middle output voltage for the V/f pattern. Determined by A1-02,C6-
01 and o2-04
(200 V Class: 0.0 - 255.0 V,
400 V Class: 0.0 - 510.0 V)
E1-09
(0308)
Minimum Output Frequency Sets the minimum output frequency for the V/f pattern. Determined by A1-02 and
E5-01
(Determined by A1-02, E1-
04, and E5-01)
E1-10
(0309)
Minimum Output Voltage Sets the minimum output voltage for the V/f pattern. Determined by A1-02
(200 V Class: 0.0 to 255.0 V,
400 V Class: 0.0 to 510.0 V)
E1-11
(030A)
Expert
Mid Point B Frequency Sets a middle output frequency for the V/f pattern. 0.0 Hz
(0.0 - E1-04)