Troubleshooting
2
2.10 Troubleshooting Without Fault Display
YASKAWA TOEPYAIGA5001A GA500 DRIVE MAINTENANCE & TROUBLESHOOTING 83
2.10 Troubleshooting Without Fault Display
Note:
Make sure that you use a keypad that has a flash number of 1004 or later. Keypads that have a flash number of 1003 or earlier will not show
characters correctly.
If the drive or motor operate incorrectly, but the keypad does not show a fault or error code, refer to the items this
section.
Motor hunting and oscillation
Unsatisfactory motor torque
Unsatisfactory speed precision
Unsatisfactory motor torque and speed response
Motor noise
Typical Problems
Symptom Reference
The Parameter Settings Will Not Change 83
The Motor Does Not Rotate after You Enter a Run Command 84
The Motor Rotates in the Opposite Direction from the Run Command 85
The Motor Rotates in Only One Direction 85
The Motor Is Too Hot 85
The Correct Auto-Tuning Mode Is Not Available 86
The Motor Stalls during Acceleration or Accel/Decel Time Is Too Long 86
The Drive Frequency Reference Is Different than the Controller Frequency Reference Command 87
PM Motor Speed Is Not Stable 87
There Is Too Much Motor Oscillation and the Rotation Is Irregular 87
Deceleration Takes Longer than Expected when You Enable Dynamic Braking 87
There Is Audible Noise from the Drive or Motor Cables when You Energize the Drive 88
The Ground Fault Circuit Interrupter (GFCI) Trips During Run 88
Motor Rotation Causes Unexpected Audible Noise from Connected Machinery 88
Motor Rotation Causes Oscillation or Hunting 88
PID Output Fault 89
The Starting Torque Is Not Sufficient 89
The Motor Rotates after You Shut Off Drive Output 89
The Output Frequency Is Lower Than the Frequency Reference 89
The Motor Will Not Restart after Power Loss 90
The Parameter Settings Will Not Change
Causes Possible Solutions
The drive is operating the motor (the drive is in Drive Mode). Stop the drive and change to Programming Mode.
Parameter A1-01 = 0 [Access Level Selection = Operation Only]. Set A1-01 = 2 [Access Level Selection = Advanced Level] or A1-01 = 3 [Expert Level].
Parameter H1-xx = 1B [MFDI Function Select = Programming Lockout]. Activate the terminals to which H1-xx = 1B is set, and then change the parameters.