EasyManua.ls Logo

YASKAWA GA500 - Derating Depending on Ambient Temperature

YASKAWA GA500
292 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7.6 Drive Derating
276 YASKAWA TOEPYAIGA5001A GA500 DRIVE MAINTENANCE & TROUBLESHOOTING
Model
Rated Current (A)
Heavy Duty Rating (HD)
[C6-01 = 0]
Normal Duty Rating (ND)
[C6-01 = 1]
2 kHz 5 kHz 8 kHz 10 kHz 12.5 kHz 15 kHz 2 kHz 5 kHz 8 kHz 10 kHz 12.5 kHz 15 kHz
4031 24.0 24.0 24.0 21.3 17.8 14.4 31.0 28.2 24.1 21.3 17.9 14.4
4038 31.0 31.0 31.0 27.5 23.0 18.6 38.0 36.3 31.0 27.5 23.0 18.6
4044 39.0 39.0 39.0 34.5 29.0 23.4 44.0 44.0 39.0 34.5 29.0 23.4
4060 45.0 45.0 45.0 39.9 33.4 27.0 60.0 54.5 46.3 40.8 33.9 27.0
Table 7.17 AOLV/PM Carrier Frequency and Rated Current Derating (Three-Phase 400 V)
Model
Rated Current (A)
Heavy Duty Rating (HD)
[C6-01 = 0]
Normal Duty Rating (ND)
[C6-01 = 1]
2 kHz 4 kHz 6 kHz 8 kHz 10 kHz 12 kHz 2 kHz 4 kHz 6 kHz 8 kHz 10 kHz 12 kHz
4001 1.2 1.2 1.1 0.9 0.7 0.5 1.2 1.2 1.1 0.9 0.7 0.5
4002 1.8 1.8 1.7 1.4 1.1 0.8 2.1 2.0 1.7 1.4 1.1 0.8
4004 3.4 3.4 3.2 2.6 2.0 1.5 4.1 3.8 3.2 2.6 2.0 1.5
4005 4.8 4.8 4.5 3.7 2.9 2.1 5.4 5.3 4.5 3.7 2.9 2.1
4007 5.5 5.5 5.2 4.2 3.3 2.4 7.1 6.2 5.2 4.3 3.3 2.4
4009 7.3 7.3 6.9 5.6 4.4 3.1 8.9 8.1 6.9 5.6 4.4 3.1
4012 9.2 9.2 8.7 7.1 5.5 3.9 11.9 10.3 8.7 7.1 5.5 3.9
4018 14.8 14.8 14.0 11.4 8.9 6.3 17.5 16.2 13.7 11.2 8.7 6.2
4023 18.0 18.0 17.0 13.9 10.8 7.7 23.4 20.3 17.1 14.0 10.8 7.7
4031 24.0 24.0 22.6 18.5 14.4 10.3 31.0 26.9 22.7 18.6 14.4 10.3
4038 31.0 31.0 29.2 23.9 18.6 13.3 38.0 34.5 29.2 23.9 18.6 13.3
4044 39.0 39.0 36.8 30.1 23.4 16.7 44.0 43.5 36.8 30.1 23.4 16.7
4060 45.0 45.0 42.4 34.7 27.0 19.3 60.0 51.8 43.5 35.3 27.0 18.8
Derating Depending on Ambient Temperature
When you install drives in these conditions, set L8-12 [Ambient Temperature Setting] and L8-35 [Installation Method
Selection].
Surrounding air temperatures are higher than the rated conditions
Install drives side-by-side in the enclosure panel
Derate the output current as specified in Figure 7.1.