3.21 Defaults by Drive Model and Duty Rating ND/HD
198 YASKAWA TOEPYAIGA5001A GA500 DRIVE MAINTENANCE & TROUBLESHOOTING
No.
*1
Name Unit Default
- Drive Model - 2042 2056 2070 2082
C6-01
Normal /
Heavy Duty
Selection
-
HD ND HD ND HD ND HD ND
0 1 0 1 0 1 0 1
o2-04
Drive Model
(KVA)
Selection
Hex. 6B 6D 6E 6F
E2-11
(E4-11, E5-
02)
Motor Rated
Power
kW 7.5 11 11 15 15 18.5 18.5 22
L3-24
Motor Accel
Time @ Rated
Torque
s 0.175 0.265 0.265 0.244 0.244 0.317 0.317 0.355
L8-02
Overheat
Alarm Level
°C 115 115 125 125 120 120 135 135
L8-09
Output Ground
Fault
Detection
- 1 1 1 1 1 1 1 1
n1-03
Hunting
Prevention
Time Constant
ms 10 10 10 10 10 10 10 10
n3-02
HSB Current
Limit Level
1 150 120 150 120 150 120 150 120
n5-02
Motor Inertia
Acceleration
Time
s 0.175 0.265 0.265 0.244 0.244 0.317 0.317 0.355
*1 Parameters within parentheses are for motor 2.
Three-Phase 400 V Class
No.
*1
Name Unit Default
- Drive Model - 4001 4002 4004 4005
C6-01
Normal /
Heavy Duty
Selection
-
HD ND HD ND HD ND HD ND
0 1 0 1 0 1 0 1
o2-04
Drive Model
(KVA)
Selection
Hex. 91 92 93 94
E2-11
(E4-11, E5-
02)
Motor Rated
Power
kW 0.2 0.4 0.4 0.75 0.75 1.5 1.5 2.2
b3-04
V/f Gain
during Speed
Search
% 100 100 100 100 100 100 100 100
b3-06
Speed
Estimation
Current Level
1
- 1.0 1.0 0.5 0.5 0.5 0.5 0.5 0.5
b3-08
Speed
Estimation
ACR P Gain
- 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
b3-26
Direction
Determination
Level
- 1000 1000 1000 1000 1000 1000 1000 1000
b8-03
Energy Saving
Filter Time
s 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
b8-04
Energy Saving
Coefficient
Value
- 713.8 576.4 576.4 447.4 447.4 338.8 338.8 313.6
C6-02
Carrier
Frequency
Selection
- 3 7 3 7 3 7 3 7
E2-01
(E4-01)
Motor Rated
Current (FLA)
A 0.6 1 1 1.6 1.6 3.1 3.1 4.2

Table of Contents