Parameter List
3
3.16 T: Motor Tuning
YASKAWA TOEPYAIGA5001A GA500 DRIVE MAINTENANCE & TROUBLESHOOTING 171
T4: EZ Tuning
No.
(Hex.)
Name Description
Default
(Range)
T4-01
(3130)
EZ Tuning Mode Selection Sets the type of Auto-Tuning for EZOLV control.
0 : Motor Parameter Setting
1 : Line-to-Line Resistance
0
(0, 1)
T4-02
(3131)
Motor Type Selection Sets the type of motor.
0 : Induction (IM)
1 : Permanent Magnet (PM)
2 : Synchronous Reluctance (SynRM)
0
(0, 1, 2)
T4-04
(3133)
Motor Rated Revolutions Sets rated rotation speed (min
-1
) of the motor. -
((40 Hz to 120 Hz) × 60 × 2/
E9-08)
T4-05
(3134)
Motor Rated Frequency Sets the rated frequency (Hz) of the motor. Determined by E9-01 and
o2-04
(40.0 - 120.0 Hz)
T4-06
(3135)
Motor Rated Voltage Sets the rated voltage (V) of the motor. 200 V Class: 230.0 V,
400 V Class: 460.0 V
(200 V Class: 0.0 - 255.0 V,
400 V Class: 0.0 - 510.0 V)
T4-07
(3136)
Motor Rated Current Sets the rated current (A) of the motor. Determined by o2-04, C6-01
(10% to 200% of the drive
rated current)
T4-08
(3137)
Motor Rated Capacity Sets the motor rated power in the units set in o1-58 [Motor Power Unit Selection]. Determined by E9-10
(0.10 - 650.00 HP)
T4-09
(3138)
Number of Poles Sets the number of motor poles. Determined by E9-01
(2 - 120)