3.8 E: Motor Parameters
118 YASKAWA TOEPYAIGA5001A GA500 DRIVE MAINTENANCE & TROUBLESHOOTING
No.
(Hex.)
Name Description
Default
(Range)
E5-03
(032B)
Motor Rated Current (FLA) Sets the PM motor rated current (FLA). Determined by o2-04, C6-01
(10% to 200% of the drive
rated current)
E5-04
(032C)
PM Motor Pole Count Sets the number of PM motor poles. 4
(2 - 120)
E5-05
(032D)
PM Motor Resistance (ohms/
phase)
Sets the resistance per phase of a PM motor. Set 50% of the line-to-line resistance. 0.100 Ω
(0.000 - 65.000 Ω)
E5-06
(032E)
PM d-axis Inductance (mH/
phase)
Sets the PM motor d-axis inductance. 1.00 mH
(0.00 - 300.00 mH)
E5-07
(032F)
PM q-axis Inductance (mH/
phase)
Sets the PM motor q-axis inductance. 1.00 mH
(0.00 - 600.00 mH)
E5-09
(0331)
PM Back-EMF Vpeak (mV/
(rad/s))
Sets the peak value of PM motor induced voltage. 0.0 mV/(rad/sec)
(0.0 - 2000.0 mV/(rad/s))
E5-24
(0353)
PM Back-EMF L-L Vrms
(mV/rpm)
Sets the RMS value for PM motor line voltage. 200 V Class:
100.0 mV/min
-1
400 V Class:
200.0 mV/min
-1
(0.0 - 6500.0 mV/min
-1
)
E5-25
(035E)
Expert
Polarity Estimation Timeout Sets the function that switches polarity for initial polarity estimation. Usually it is not necessary to
change this setting.
0 : Disabled
1 : Enabled
0
(0, 1)
E9: Motor Setting
No.
(Hex.)
Name Description
Default
(Range)
E9-01
(11E4)
Motor Type Selection Sets the type of motor.
0 : Induction (IM)
1 : Permanent Magnet (PM)
2 : Synchronous Reluctance (SynRM)
0
(0 - 2)
E9-02
(11E5)
Maximum Speed Sets the maximum speed of the motor. Determined by E9-01
(40.0 - 120.0 Hz)
E9-03
(11E6)
Rated Speed Sets the rated rotation speed of the motor. Determined by E9-01
(100 - 7200 min
-1
)
E9-04
(11E7)
Base Frequency Sets the rated frequency of the motor. Determined by E9-01
(40.0 - 120.0 Hz)
E9-05
(11E8)
Motor Rated Voltage Sets the rated voltage of the motor. 200 V Class: 230.0 V,
400 V Class: 460.0 V
(200 V Class: 0.0 - 255.0 V,
400 V Class: 0.0 - 510.0 V)
E9-06
(11E9)
Motor Rated Current (FLA) Sets the motor rated current in amps. Determined by E9-01 and
o2-04
(10% to 200% of the drive
rated current)
E9-07
(11EA)
Motor Rated Power Sets the motor rated output in the units from o1-58 [Motor Power Unit Selection]. Determined by E9-02 and
o2-04
(0.00 - 650.00 kW)
E9-08
(11EB)
Motor Pole Count Sets the number of motor poles. 4
(2 to 120)
E9-09
(11EC)
Motor Rated Slip Sets the motor rated slip. 0.000 Hz
(0.000 - 20.000 Hz)
E9-10
(11ED)
Motor Line-to-Line
Resistance
Sets the line-to-line resistance for the motor stator windings. Determined by o2-04
(0.000 - 65.000 Ω)

Table of Contents