3.11 L: Protection Functions
154 YASKAWA TOEPYAIGA5001A GA500 DRIVE MAINTENANCE & TROUBLESHOOTING
No.
(Hex.)
Name Description
Default
(Range)
L8-94
(073D)
Expert
Low Speed Pull-out Detect
Level
Sets the detection level for LSo [Low Speed Motor Step-Out] as a percentage of E1-04 [Maximum
Output Frequency].
3%
(0 - 10%)
L8-95
(077F)
Expert
Low Speed Pull-out Amount Sets the average count of LSo [Low Speed Motor Step-Out] detections. 10
(1 - 50 times)