Specifications
7
7.5 Drive Specifications
YASKAWA TOEPYAIGA5001A GA500 DRIVE MAINTENANCE & TROUBLESHOOTING 273
Item Specification
Altitude
1000 m (3281 ft) Maximum
Note:
Derate the output current by 1% for each 100 m (328 ft) to install the drive in altitudes between 1000 m to 4000 m (3281 ft to 13123 ft).
It is not necessary to derate the rated voltage in these conditions:
Installing the drive at 2000 m (6562 ft) or lower
Installing the drive between 2000 m to 4000 m (6562 ft to 13123 ft) and grounding the neutral point on the power supply.
Contact Yaskawa or your nearest sales representative if you will not ground the neutral point.
Vibration
10 Hz to 20 Hz: 1 G (9.8 m/s
2
, 32.15 ft/s
2
)
20 Hz to 55 Hz: 0.6 G (5.9 m/s
2
, 19.36 ft/s
2
)
Installation
Orientation
Install the drive vertically for sufficient airflow to cool the drive.
Table 7.11 Standard
Item Specification
Applicable Standards
UL 61800-5-1
EN 61800-3
EN 61800-5-1
Two Safe Disable inputs and one EDM output according to EN ISO 13849-1 (Cat.3, PL e), EN 61800-5-2 SIL3
Enclosure Protection
Design
IP20/UL Open Type
IP20/UL Type 1
Note:
Install a UL Type 1 kit (optional) on an IP20/UL Open Type drive to change the drive to an IP20/UL Type 1 enclosure.