Parameter List
3
3.4 A: Initialization Parameters
YASKAWA TOEPYAIGA5001A GA500 DRIVE MAINTENANCE & TROUBLESHOOTING 97
No.
(Hex.)
Name Description
Default
(Setting Range)
A2-27
(0120)
User Parameter 27 Sets the parameter number to show on the 27th line in Setup Mode. You can select a maximum of 32
parameters for the drive and set them to parameters A2-01 to A2-32.
-
(Determined by A1-06)
A2-28
(0121)
User Parameter 28 Sets the parameter number to show on the 28th line in Setup Mode. You can select a maximum of 32
parameters for the drive and set them to parameters A2-01 to A2-32.
-
(Determined by A1-06)
A2-29
(0122)
User Parameter 29 Sets the parameter number to show on the 29th line in Setup Mode. You can select a maximum of 32
parameters for the drive and set them to parameters A2-01 to A2-32.
-
(Determined by A1-06)
A2-30
(0123)
User Parameter 30 Sets the parameter number to show on the 30th line in Setup Mode. You can select a maximum of 32
parameters for the drive and set them to parameters A2-01 to A2-32.
-
(Determined by A1-06)
A2-31
(0124)
User Parameter 31 Sets the parameter number to show on the 31st line in Setup Mode. You can select a maximum of 32
parameters for the drive and set them to parameters A2-01 to A2-32.
-
(Determined by A1-06)
A2-32
(0125)
User Parameter 32 Sets the parameter number to show on the 32nd line in Setup Mode. You can select a maximum of 32
parameters for the drive and set them to parameters A2-01 to A2-32.
-
(Determined by A1-06)
A2-33
(0126)
User Parameter Auto
Selection
Sets the automatic save feature for changes to parameters A2-17 to A2-32 [User Parameters 17 to
32].
0 : Disabled: Manual Entry Required
1 : Enabled: Auto Save Recent Parms
Determined by A1-06
(0, 1)