10.2 Operation of Digital Operator
10.2.2 Operation of Utility Functions
10-18
ZONE Table Initialization (Fn064)
This function initializes ZONE tables and restores the default settings.
Preparation
The following conditions must be met to initialize ZONE tables.
• The write-prohibited setting (Fn010) must not be set to write-protect parameters.
• A ZONE table initialization must not be in progress for any means other than the digital oper-
ator.
Operating Procedure
* If the key is pressed in an operation prohibited state, “Error.” is displayed for approximately 2 seconds and
then the display returns to the Fn064 operation screen. In this case, make the setting again by referring to
Preparation.
Step Display after Operation Keys Operation
1
Press the key to open the Utility Function
Mode main menu, and move the cursor with the
keys to select Fn064.
2
Press the key to view the Fn064 operation
screen.
3
Press the key to start ZONE table initializa-
tion.*
Do not turn OFF the control power supply until
initialization has been completed normally.
To cancel the Fn064 operation, press the
key before pressing the key. The display
returns to the Utility Function Mode main menu
without executing the operation.
4 –
When ZONE table initialization has been com-
pleted normally, “Done.” is displayed.
5
Press the key to return to the Utility Function
Mode main menu.