6.2 Troubleshooting
395
Status When Alarm Occurred
A
During servomotor
operation
Overflow during
high-speed opera-
tion
No feedback pulse
returned after refer-
ence pulse input.
Normal operation
but overflow when
large reference in-
put.
At control power ON
B
,
F
C
,
D
,
E
F
Cause Remedy
A Servomotor wiring incorrect.
Check and correct wiring. (Check A-, B-,
B Encoder wiring incorrect (disconnection,
short, power supply, etc.)
C-phase pulses correct at 2CN.)
C Servopack adjustment incorrect Increase speed loop gain (Cn-04) and/or
position loop gain (Cn-1A).
D Servomotor overloaded Reduce load torque and inertia. Otherwise,
replace with larger capacity servomotor.
E Position reference pulse frequency too
high
• Decrease reference pulse frequency.
• Use smoothing function.
• Change electronic gear ratio.
F Circuit board (1PWB) defective. Replace Servopack.
D Display and Outputs
Digital Operator
Alarm Output
Display and
Alarm Code Output
Alarm Output
arm
ame
ALO1 ALO2 ALO3
A.40
Overvoltage
OFF OFF ON OFF
OFF: Output transistor is OFF
ON: Output transistor is ON