INSPECTION, MAINTENANCE, AND TROUBLESHOOTING
6.2.1 Troubleshooting Problems with Alarm Display cont.
404
D Display and Outputs
Digital Operator
Alarm Output
Display and
Alarm Code Output
Alarm Output
arm
ame
ALO1 ALO2 ALO3
A.C2
Encoder phase
detection error
Incremental
encoder initial
pulse error
ON OFF ON OFF
OFF: Output transistor is OFF
ON: Output transistor is ON
Status When Alarm Occurred
During servomotor
operation
A
,
B
,
C
At control power ON
During servomotor
operation
Occurred 1 to 3 seconds
after control power ON
D, E
,
F, G ,
H
E, F, G,
H
Cause Remedy
A Noise in encoder wiring. Separate encoder wiring from main wiring
circuits.
B Encoder wiring incorrect or poor
connection
Check wiring and connectors at encoder.
C Encoder defective Replace servomotor.
D Noise in encoder wiring. Separate encoder wiring from main wiring
circuits.
E Encoder wiring incorrect or poor
connection
Check wiring and connectors at encoder.
F Encoder defective Replace servomotor.
G Absolute encoder is used. Set the following user constants as
follows:
SCn-02 bit 9 = 1
SCn-11 (number of encoder pulses)
6