4.6 Test Without Motor Function
4-15
4
Trial Operation
4.6.4 Operator Displays during Testing without Motor
The status display changes as shown below to show that the test without a motor is being executed.
(1) Display on Panel Operator
The test without a motor operation in progress is indicated with tSt.
  
Note: The test without a motor status is not displayed during alarm occurs (A.).
(2) Display on Digital Operator
An asterisk () is displayed before status display to indicate the test without a motor operation is in progress.
(Example: Status of power to the servomotor is OFF)
Note: The test without a motor status is not displayed during alarm occurs (A.).
Display Status
run tSt
Power is supplied to the servomotor.
bb tSt
Power to the servomotor is OFF.
Pot not tSt
Forward or reverse run is prohibited.
Pot tSt
Forward run is prohibited.
not tSt
Reverse run is prohibited.
Hbb tSt
In hard-wire base block (safety) state.
Displayed alternately
Analog
Display Status
*RUN Power is supplied to the servomotor.
*BB Power to the servomotor is OFF.
*PT NT Forward or reverse run is prohibited.
*P-OT Forward run is prohibited.
*N-OT Reverse run is prohibited.
*HBB In hard-wire base block (safety) state.
BB
PRM/MON
Un000=0 00000
Un002=0 00000
Un008=0 0000000000
Un00D=0 0000000000

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA Sigma-V Series and is the answer not in the manual?

YASKAWA Sigma-V Series Specifications

General IconGeneral
BrandYASKAWA
ModelSigma-V Series
CategoryServo Drives
LanguageEnglish

Related product manuals