EasyManua.ls Logo

YASKAWA Sigma-V Series - Parameters

YASKAWA Sigma-V Series
434 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11 Appendix
11.2.2 Parameters
11-10
11.2.2 Parameters
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When Enabled
Classifi-
cation
Reference
Section
Pn000
2 Basic Function Select Switch 0 0000 to 00B3 0000 After restart Setup
Direction Selection
Reference
Section
0 Sets CCW as forward direction.
5.2.2
1 Sets CW as forward direction. (Reverse Rotation Mode)
2 to 3 Reserved (Do not set.)
Control Method Selection
Reference
Section
0 Speed control (analog reference)
5.7
1 Position control (pulse train reference)
2 Torque control (analog reference)
3 Internal set speed control (contact reference)
4 Internal set speed control (contact reference) Speed control (analog reference)
5 Internal set speed control (contact reference) Position control (pulse train reference)
6 Internal set speed control (contact reference) Torque control (analog reference)
7 Position control (pulse train reference) Speed control (analog reference)
8 Position control (pulse train reference) Torque control (analog reference)
9 Torque control (analog reference) Speed control (analog reference)
A Speed control (analog reference) Speed control with zero clamp function
B Position control (pulse train reference) Position control with reference pulse inhibit
function
Reserved (Do not change.)
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.


Table of Contents