5.2 Basic Functions Settings
5-19
5
Operation
(2) Related Parameters
The setting unit is a percentage of the rated torque.
Note: When using SEMI F47 function, set 1000 ms.
Parameter Meaning When Enabled Classification
Pn008
n.0
[Factory setting]
Does not detect undervoltage.
After restart Setup
n.1 Detects warning and limits torque by host controller.
n.2
Detects warning and limits torque by Pn424 and Pn425.
(Only in the SERVOPACK)
Pn424
Torque Limit at Main Circuit Voltage Drop
Classification
Setting Range Setting Unit Factory Setting When Enabled
0 to 100
1%
*
50 Immediately Setup
Pn425
Release Time for
Torque
Limit at Main Circuit
Voltage Drop
Classification
Setting Range Setting Unit Factory Setting When Enabled
0 to 1000 1 ms 100 Immediately Setup
Pn509
Instantaneous Power Cut Hold Time
Classification
Setting Range Setting Unit Factory Setting When Enabled
20 to 50000 1 ms 20 Immediately Setup
Speed
Position
Torque
Speed
Position
Torque
Speed
Position
Torque

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA Sigma-V Series and is the answer not in the manual?

YASKAWA Sigma-V Series Specifications

General IconGeneral
BrandYASKAWA
ModelSigma-V Series
CategoryServo Drives
LanguageEnglish

Related product manuals