xvi
 Safety Standards
 Safe Performance
Name (Model) Safety Standards Standards Remarks
SERVOPACK (SGDV-H, 
-J),
Converter (SGDV-COA)
Safety of Machinery
EN ISO13849-1: 2008,
EN 954-1,
IEC 60204-1
Application pending.
Functional Safety
IEC 61508 series,
IEC 62061,
IEC 61800-5-2
EMC IEC 61326-3-1
Items Standards Performance Level
Safety Integrity Level
IEC 61508  SIL2
IEC 62061  SILCL2
Probability of Dangerous Failure per Hour
IEC 61508,
IEC 62061 
PFH ⇐ 1.7×10
-9 
[1/h]
 (0.17% of SIL2)
Category EN 954-1  Category 3
Performance Level EN ISO 13849-1  PL d (Category 3)
Mean Time to Dangerous Failure of Each 
Channel
EN ISO 13849-1 MTTFd: High 
Average Diagnostic Coverage EN ISO 13849-1 DCave: Low
Stop Category IEC 60204-1  Stop category 0
Safety Function IEC 61800-5-2  STO
Proof test Interval IEC 61508 10 years