7.9 Gain Adjustment of Analog Monitor Output (Fn00D)
7-17
7
Utility Functions (Fn)
(3) Operating Procedure
Use the following procedure to perform the gain adjustment of analog monitor output.
Step
Display after
Operation
Keys Operation
1 Press the MODE/SET Key to select the utility function.
2 Press the UP or DOWN Key to select Fn00D.
3
Press the DATA/SHIFT Key for approximately one second.
The screen shown on the left will be displayed.
4
Press the DATA/SHIFT Key. Gain adjustment data will be
displayed as shown on the left.
5 Press the UP or DOWN Key to change the gain.
6
Press the DATA/SHIFT Key to return to the screen as
shown on the left.
7
Press the MODE/SET Key to switch to channel 2 (analog
monitor 2) monitor output.
8
Press the DATA/SHIFT Key. Gain adjustment data will be
displayed as shown on the left.
9 Press the UP or DOWN Key to change the gain.
10
Press the DATA/SHIFT Key for approximately one second.
"Ch2-G" is displayed, and then "Fn00D" is displayed again.