EasyManuals Logo

YASKAWA Sigma-V Series User Manual

YASKAWA Sigma-V Series
434 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #307 background imageLoading...
Page #307 background image
7 Utility Functions (Fn)
7-22
(1) Preparation
There are no tasks that must be performed before the execution.
(2) Operating Procedure
Follow the steps to set enable or disable writing.
Setting values are as follows:
"P.0000": Write permitted (Releases write prohibited mode.) [Factory setting]
"P.0001": Write prohibited (Parameters become write prohibited from the next power ON.)
Step
Display after
Operation
Keys Operation
1 Press the MODE/SET Key to select the utility function.
2 Press the UP or DOWN Key to select Fn010.
3
Press the DATA/SHIFT Key for approximately one second.
The display shown on the left appears.
4
Press the UP or DOWN Key to set a value:
P.0000: Write permitted [Factory setting]
P.0001: Write prohibited
5
Press the MODE/SET Key to register the value. When the
setting has been completed, "donE" flashes on the display
and the screen returns to the state shown on the left.
Note: If any value other than P.0000 or P.0001 is set,
"Error" will be displayed on the screen.
6 To enable the change in the setting, turn the power OFF and ON again.
MODE
/
SET
DATA
/
MODE
/
SET
DATA
/
MODE
/
SET
DATA
/
MODE
/
SET
DATA
/
MODE
/
SET
DATA
/

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA Sigma-V Series and is the answer not in the manual?

YASKAWA Sigma-V Series Specifications

General IconGeneral
BrandYASKAWA
ModelSigma-V Series
CategoryServo Drives
LanguageEnglish

Related product manuals