7.22 Online Vibration Monitor (Fn207)
7-39
7
Utility Functions (Fn)
(3) Related Parameters
The following table lists parameters related to this function and their possibility of being changed while exe-
cuting this function or of being changed automatically after executing this function.
Parameters related to this function
These are parameters that are used or referenced when executing this function.
Allowed changes during execution of this function
Yes : Parameters can be changed using SigmaWin+ while this function is being executed.
No : Parameters cannot be changed using SigmaWin+ while this function is being executed.
Automatic changes after execution of this function
Yes : Parameter set values are automatically set or adjusted after execution of this function.
No : Parameter set values are not automatically set or adjusted after execution of this function.
Parameter Name
Mid-execution
changes
Automatic
changes
Pn401 Torque Reference Filter Time Constant No Yes
Pn408 Torque Related Function Switch Yes Yes
Pn409 1st Notch Filter Frequency No Yes
Pn40A 1st Notch Filter Q Value No No
Pn40C 2nd Notch Filter Frequency No No
Pn40D 2nd Notch Filter Q Value No No

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA Sigma-V Series and is the answer not in the manual?

YASKAWA Sigma-V Series Specifications

General IconGeneral
BrandYASKAWA
ModelSigma-V Series
CategoryServo Drives
LanguageEnglish

Related product manuals