81
96.04 Macro select 2 =
Hand/Auto
3 =
Hand/PID
14 =
PID
15 =
Panel PID
16 =
PFC
10.24 RO1 source 2=Ready run 2=Ready run 2=Ready run 2=Ready run 7=Running
10.27 RO2 source 7=Running 7=Running 7=Running 7=Running 15 = Fault (-1)
10.30 RO3 source 15 = Fault (-1) 15 = Fault (-1) 15 = Fault (-1) 15 = Fault (-1) 44 = PFC2
12.20 AI1 scaled at AI1
max
50.0 50.0 50.0 50.0 50.0
13.12 AO1 source 2 = Output
frequency
2 = Output
frequency
2 = Output
frequency
2 = Output
frequency
2 = Output
frequency
13.18 AO1 source max 50.0 50.0 50.0 50.0 50.0
19.11 Ext1/Ext2
selection
5 = DI3 4 = DI2 0 = EXT1 0 = EXT1 1 = EXT2
20.01 Ext1 commands 2 = In1 Start;
In2 Dir
1 = In1 Start 1 =In1 Start 1 =In1 Start 1 =In1 Start
20.03 Ext1 in1 source 2 = DI1 2 = DI1 2 = DI1 2 = DI1 2 = DI1
20.04 Ext1 in2 source 3 = DI2 0 = Not
selected
0 = Not
selected
0 = Not
selected
0 = Not
selected
20.05 Ext1 in3 source 0 = Not
selected
0 = Not
selected
0 = Not
selected
0 = Not
selected
0 = Not
selected
20.06 Ext2 commands 2 = In1 Start;
In2 Dir
1 = In1 Start 0 = Not
selected
0 = Not
selected
1 = In1 Start
20.08 Ext2 in1 source 7 = DI6 7 = DI6 0 = Not
selected
0 = Not
selected
7 = DI6
20.09 Ext2 in2 source 6 = DI5 0 = Not
selected
0 = Not
selected
0 = Not
selected
0 = Not
selected
20.12 Run enable 1
source
5 = DI4 6 = DI5 6 = DI5 6 = DI5 3 = DI2
22.11 Ext1 speed ref1 1 = AI1 scaled 1 = AI1 scaled 16 = PID 16 = PID 16 = PID
22.18 Ext2 speed ref1 2 = AI2 scaled 16 = PID 0 = Zero 0 = Zero 16 = PID
22.22 Constant speed
sel1
0 = Not
selected
4 = DI3 5 = DI4 5 = DI4 0 = Not
selected
22.23 Constant speed
sel2
0 = Not
selected
5 = DI4 0 = Not
selected
0 = Not
selected
0 = Not
selected
ACS580 FW.book Page 81 Wednesday, September 21, 2016 9:48 PM