82
96.04 Macro select 1 =
ABB standard
17 =
ABB stan-
dard (vector)
11 =
3-wire
12 =
Alternate
1
3 =
Motor potenti-
ometer
22.71 Motor
potentiometer
function
0 = Disabled 0 = Disabled 0 = Disabled 0 = Disabled 1 = Enabled
(init at stop
/power-up)
22.73 Motor
potentiometer up
source
0 = Not
selected
0 = Not
selected
0 = Not
selected
0 = Not
selected
4 = DI3
22.74 Motor
potentiometer
down source
0 = Not
selected
0 = Not
selected
0 = Not
selected
0 = Not
selected
5 = DI4
28.11 Ext1 frequency
ref1
1 = AI1 scaled 1 = AI1 scaled 1 = AI1 scaled 1 = AI1 scaled 15 = Motor
potentiometer
28.15 Ext1 frequency
ref2
0 = Zero 0 = Zero 0 = Zero 0 = Zero 0 = Zero
28.22 Constant
frequency sel1
4 = DI3 4 = DI3 5 = DI4 4 = DI3 6 = DI5
28.23 Constant
frequency sel2
5 = DI4 5 = DI4 6 = DI5 5 = DI4 0 = Not
selected
28.71 Freq ramp set
selection
6 = DI5 6 = DI5 0 = Acc/Dec
time 1
6 = DI5 0 = Acc/Dec
time 1
40.07 Process PID
operation mode
0 = Off 0 = Off 0 = Off 0 = Off 0 = Off
40.16 Set 1 setpoint 1
source
11 = AI1
percent
11 = AI1
percent
11 = AI1
percent
11 = AI1
percent
11 = AI1
percent
40.17 Set 1 setpoint 2
source
0 = Not
selected
0 = Not
selected
0 = Not
selected
0 = Not
selected
0 = Not
selected
40.19 Set 1 internal
setpoint sel1
0 = Not
selected
0 = Not
selected
0 = Not
selected
0 = Not
selected
0 = Not
selected
40.20 Set 1 internal
setpoint sel2
0 = Not
selected
0 = Not
selected
0 = Not
selected
0 = Not
selected
0 = Not
selected
40.32 Set 1 gain 1.00 1.00 1.00 1.00 1.00
40.33 Set 1 integration
time
60.0 60.0 60.0 60.0 60.0
76.21 PFC configuration 0=Off 0=
Off 0=Off 0=Off 0=Off
76.25 Number of motors 11111
76.27 Max number of
motors allowed
11111