Parameters 407
61.26 M/F data 2 value Displays the data to be sent onto the master/follower link as
word 2 as an integer.
If no data has been preselected by 61.02 M/F data 2
selection, the value to be sent can be written directly into this
parameter.
0
0…65535 Data to be sent as word 2 in master/follower communication.
61.27 M/F data 3 value Displays the data to be sent onto the master/follower link as
word 3 as an integer.
If no data has been preselected by 61.03 M/F data 3
selection, the value to be sent can be written directly into this
parameter.
0
0…65535 Data to be sent as word 3 in master/follower communication.
61.45 Data set 2 data 1
selection
Parameters 61.45…61.50 preselect data to be sent in data
sets 2 and 4 to the external controller. These data sets are
used in ModuleBus communication with a “standard drive”
(60.50 DDCS controller drive type = ABB standard drive).
Parameters 61.95…61.100 display the data to be sent to the
external controller. If no data has been preselected, the value
to be sent can be written directly into these parameters.
For example, this parameter preselects the data for word 1 of
data set 2. Parameter 61.95 Data set 2 data 1 value displays
the selected data in integer format. If no data is preselected,
the value to be sent can be written directly into parameter
61.95.
None
None None. 0
CW 16bit Control Word (16 bits) 1
SW 16bit Status Word (16 bits) 4
Act1 16bit Actual value ACT1 (16 bits) 5
Act2 16bit Actual value ACT2 (16 bits) 6
Other Source selection (see Terms and abbreviations on page 148). -
61.46 Data set 2 data 2
selection
Preselects the data to be sent as word 2 of data set 2 to the
external controller.
See also parameter 61.96 Data set 2 data 2 value.
For the selections, see parameter 61.45 Data set 2 data 1
selection.
None
61.47 Data set 2 data 3
selection
See parameter 61.45 Data set 2 data 1 selection. None
…… … …
61.50 Data set 4 data 3
selection
See parameter 61.45 Data set 2 data 1 selection. None
61.51 Data set 11 data 1
selection
Parameters 61.51…
61.74 preselect data to be sent in data
sets 11, 13, 15, 17, 19, 21, 23 and 25 to the external
controller.
Parameters 61.101…61.124 display the data to be sent to the
external controller. If no data has been preselected, the value
to be sent can be written directly into these parameters.
For example, this parameter preselects the data for word 1 of
data set 11. Parameter 61.101 Data set 11 data 1 value
displays the selected data in integer format. If no data is
preselected, the value to be sent can be written directly into
parameter 61.101.
None
None None. 0