Parameters 439
80.22 Additive voltage 2 Defines voltage additive point 2 in the custom user U/F curve. 0.00
-100.00...100.00 % Additive voltage 2. 10 = 1%
80.23 Additive voltage 3 Defines voltage additive point 3 in the custom user U/F curve. 0.00
-100.00...100.00 % Additive voltage 3. 10 = 1%
80.24 Additive voltage 4 Defines voltage additive point 4 in the custom user U/F curve. 0.00
-100.00...100.00 % Additive voltage 4. 10 = 1%
80.25 Additive voltage 5 Defines voltage additive point 5 in the custom user U/F curve. 0.00
-100.00...100.00 % Additive voltage 5. 10 = 1%
80.26 Additive voltage 6 Defines voltage additive point 6 in the custom user U/F curve. 0.00
-100.00...100.00 % Additive voltage 6. 10 = 1%
80.27 Additive voltage 7 Defines voltage additive point 7 in the custom user U/F curve. 0.00
-100.00...100.00 % Additive voltage 7. 10 = 1%
80.28 Additive voltage 8 Defines voltage additive point 8 in the custom user U/F curve. 0.00
-100.00...100.00 % Additive voltage 8. 10 = 1%
80.31 Validate tuning cmd Defines the source for U/F curve tuning command.
This parameter provides possibility to manually tune the U/F
curve point settings while motor is running. When this
parameter is activated, the value received from parameter
80.32 Voltage tuner source is taken as the voltage additive. It
is converted to motor flux reference and applied instantly
instead of the value set in the u/f curve.
After tuning command is disabled, the actual motor speed
frequency is automatically written to the nearest frequency
point in the U/F curve and the voltage correction used at that
moment is then written to corresponding Additive voltage
parameter setting.
Not selected
Not selected Validate tuning cmd is not selected. 0
Selected Validate tuning cmd is selected. 1
DI1 Digital input DI1 (10.02 DI delayed status, bit 0). 2
DI2 Digital input DI2 (10.02 DI delayed status, bit 1). 3
DI3 Digital input DI3 (10.02 DI delayed status, bit 2). 4
DI4 Digital input DI4 (10.02 DI delayed status, bit 3). 5
DI5 Digital input DI5 (10.02 DI delayed status, bit 4). 6
DI6 Digital input DI6 (10.02 DI delayed status, bit 5). 7
DIO1 Digital input/output DIO1 (11.02 DIO delayed status, bit 0). 8
DIO2 Digital input/output DIO2 (11.02 DIO delayed status, bit 1). 9
Other Source selection (see Terms and abbreviations on page 148). -
80.32 Voltage tuner
source
Defines the source for the voltage tuner signal.
This is used as additive voltage when parameter 80.31
Validate tuning cmd is active.
NULL
NULL Zero 0
AI1 scaled See parameter 12.12 AI1 scaled value (see page 197). 1
AI2 scaled See parameter 12.22 AI2 scaled value (see page 199). 2
FBA1 ref See parameter 03.05 FB A reference 1 (page 156). 3
FBA2 ref See parameter 03.06 FB A reference 2 (page 156). 4
No. Name/Value Description Def/FbEq16