464 Parameters
HTL 1 HTL. Module type (input): FSE-31 (X31). 6
HTL 2 HTL. Module type (input): FSE-31 (X32). Not supported at the
time of publication.
7
92.02 Encoder 1 source Selects the interface module that the encoder is connected
to. (The physical locations and types of encoder interface
modules are defined in parameter group 91 Encoder module
settings.)
Module 1
Module 1 Interface module 1. 0
Module 2 Interface module 2. 1
92.10 Pulses/revolution (Visible when a TTL, TTL+ or HTL encoder is selected)
Defines the pulse number per revolution.
2048
0…65535 Number of pulses. -
92.10 Sine/cosine number (Visible when an absolute encoder is selected)
Defines the number of sine/cosine wave cycles within one
revolution.
Note: This parameter need not be set when an EnDat or SSI
encoder is used in continuous mode. See parameter 92.30
Serial link mode.
0
0…65535 Number of sine/cosine wave cycles within one revolution. -
92.10 Excitation signal
frequency
(Visible when a resolver is selected)
Defines the frequency of the excitation signal.
Note: With an EnDat or HIPERFACE encoder and FEN-11
FPGA version VIE12200 or later, this parameter is
automatically set upon validation of encoder settings (91.10
Encoder parameter refresh).
1 kHz
1…20 kHz Excitation signal frequency. 1 = 1 kHz
92.11 Pulse encoder type (Visible when a TTL, TTL+ or HTL encoder is selected)
Selects the type of encoder.
Quadrature
Quadrature Quadrature encoder (with two channels, A and B) 0
Single track Single-track encoder (with one channel, A).
Note: With this setting, the measured speed value is always
positive regardless of direction of rotation.
1
92.11 Absolute position
source
(Visible when an absolute encoder is selected)
Selects the source of the absolute position information.
None
None Not selected. 0
Commut signals Commutation signals. 1
EnDat Serial interface: EnDat encoder. 2
Hiperface Serial interface: HIPERFACE encoder. 3
SSI Serial interface: SSI encoder. 4
Tamagawa Serial interface: Tamagawa 17/33-bit encoder. 5
92.11 Excitation signal
amplitude
(Visible when a resolver is selected)
Defines the rms amplitude of the excitation signal.
4.0 V
4.0 … 12.0 V Excitation signal amplitude. 10 = 1 V
No. Name/Value Description Def/FbEq16