EasyManua.ls Logo

ABB ACS880-104

ABB ACS880-104
664 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
464 Parameters
HTL 1 HTL. Module type (input): FSE-31 (X31). 6
HTL 2 HTL. Module type (input): FSE-31 (X32). Not supported at the
time of publication.
7
92.02 Encoder 1 source Selects the interface module that the encoder is connected
to. (The physical locations and types of encoder interface
modules are defined in parameter group 91 Encoder module
settings.)
Module 1
Module 1 Interface module 1. 0
Module 2 Interface module 2. 1
92.10 Pulses/revolution (Visible when a TTL, TTL+ or HTL encoder is selected)
Defines the pulse number per revolution.
2048
0…65535 Number of pulses. -
92.10 Sine/cosine number (Visible when an absolute encoder is selected)
Defines the number of sine/cosine wave cycles within one
revolution.
Note: This parameter need not be set when an EnDat or SSI
encoder is used in continuous mode. See parameter 92.30
Serial link mode.
0
0…65535 Number of sine/cosine wave cycles within one revolution. -
92.10 Excitation signal
frequency
(Visible when a resolver is selected)
Defines the frequency of the excitation signal.
Note: With an EnDat or HIPERFACE encoder and FEN-11
FPGA version VIE12200 or later, this parameter is
automatically set upon validation of encoder settings (91.10
Encoder parameter refresh).
1 kHz
1…20 kHz Excitation signal frequency. 1 = 1 kHz
92.11 Pulse encoder type (Visible when a TTL, TTL+ or HTL encoder is selected)
Selects the type of encoder.
Quadrature
Quadrature Quadrature encoder (with two channels, A and B) 0
Single track Single-track encoder (with one channel, A).
Note: With this setting, the measured speed value is always
positive regardless of direction of rotation.
1
92.11 Absolute position
source
(Visible when an absolute encoder is selected)
Selects the source of the absolute position information.
None
None Not selected. 0
Commut signals Commutation signals. 1
EnDat Serial interface: EnDat encoder. 2
Hiperface Serial interface: HIPERFACE encoder. 3
SSI Serial interface: SSI encoder. 4
Tamagawa Serial interface: Tamagawa 17/33-bit encoder. 5
92.11 Excitation signal
amplitude
(Visible when a resolver is selected)
Defines the rms amplitude of the excitation signal.
4.0 V
4.0 … 12.0 V Excitation signal amplitude. 10 = 1 V