CAUTION
Always cut the paint with a knife and grind the paint edge when disassembling
parts. See Cut the paint or surface on the robot before replacing parts on page 140.
WARNING
If the mechanical stop has been deformed after a hard collision, it must be
replaced!
WARNING
When the damper is removed from axis 4, the axis does not have a mechanical
stop! If the robot is provided with cabling on the upper arm, the cabling can be
damaged when the function Resetting the work area for an axis is used, or if the
robot is jogged uncalibrated.
Removal, mechanical stop
The procedure below details how to remove the axis 4 mechanical stop from the
robot.
Info/IllustrationAction
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply (do not turn off for Foundry
Prime robots!)
to the robot, before entering the robot working area.
1
Shown in the figure Location
of mechanical stop on
page 173.
Remove the mechanical stop by removing its attach-
ment screws.
2
Shown in the figure Location
of mechanical stop on
page 173.
Rotate axis 4 so that the damper is visible. Remove
the damper.