EasyManua.ls Logo

Adtech iMASTER – A1 Series - Page 127

Default Icon
198 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A1-User’s Manual
123
22.34 UP/DOWN ref reset source
0: Not selected ----- Initial value
1: Selected
2: DI1
3: DI2
4: DI3
5: DI4
6; DI5
7: DI6
8: DI7
9: DI8
Selects the source of the UP/DOWN ref reset
It is not works when the up or down source has inputted
Set 0: Not selected
Always off
Set 1: selected
Always on
Set 2~9 : DI1~ DI8
It works by digital input which is selected
UP
reset
Output frequency
UP/DOWN ref
Run command
ON
ON ON
ON
ON
ON
ON
ON

Table of Contents