AESFill AF1C Machine Manual 46/58 Cleaning & Accessories
9. Feed Tanks
You may have requested a feed tank be supplied with your AESFill AF1 unit(s). If you have multiple fillers, the feed tank should have
multiple outlets on the bottom. Each AESFill AF1 should be attached to its own outlet at the bottom of the tank. Do not attach more
than one pump to an individual outlet, as this can cause pump starvation, leading to inaccurate filling, and possible pump damage.
If you are filling from a drum or barrel, place the infeed hose as close to the bottom as possible. It is advisable to cut the hose at an
angle to avoid it sucking itself to the bottom of the drum.