258 Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide
16 Waveform Generator
 
1 Press Point #; then, use the Entry knob to select the point whose voltage 
value you wish to set.
2 Press  Voltage; then, use the Entry knob to set the point's voltage value.
To insert a point:
1 Press  Point #; then, use the Entry knob to select the point after which 
the new point will be inserted.
2 Press  Insert Point.
All points are adjusted to maintain uniform time spacing between 
points.
To remove a point:
1 Press  Point #; then, use the Entry knob to select the point you want to 
remove.
2 Press  Remove Point.
All points are adjusted to maintain uniform time spacing between 
points.
The Transparen t softkey enables or disables transparent backgrounds. When 
enabled, you can view underlying waveforms. When disabled, the 
background is shaded.
Capturing Other Waveforms to the Arbitrary Waveform
The Edit Waveform Menu is opened by pressing Edit Waveform in the main 
Waveform Generator Menu.
To capture another waveform to the arbitrary waveform:
1 Press  Source; then, use the Entry knob to select the analog channel, 
math, or reference location whose waveform you wish to capture.
2 Press  Store Source to Arb.