166 Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide
10 Triggers
 
To set up Generic video triggers
When  Generic (available with the DSOX3VID extended video triggering 
license) is selected as the Video trigger Standard, you can trigger on custom 
bi- level and tri- level sync video standards. The Video Trigger Menu 
changes as follows.
1 Press the Time > softkey; then, turn the Entry knob to set the time to 
greater-than the sync- pulse width so that the oscilloscope synchronizes 
to the vertical sync.
2 Press the Edge # softkey; then, turn the Entry knob to select the Nth 
edge after after vertical sync to trigger on.
3 To enable or disable the horizontal sync control, press the first 
Horiz Sync softkey.
• For interleaved video, enabling the Horiz Sync control and setting the 
Horiz Sync adjustment to the sync time of the probed video signal 
allows the Edge # function to count only lines and not double count 
during equalization. Additionally, the Field Holdoff can be adjusted so 
that the oscilloscope triggers once per frame.
• Similarly, for progressive video with a tri-level sync, enabling the 
Horiz Sync control and setting the Horiz Sync adjustment to the sync 
time of the probed video signal allows the Edge # function to count 
only lines and not double count during vertical sync.
When the horizontal sync control is enabled, press the second Horiz Sync 
softkey; then, turn the Entry knob to set the minimum time the 
horizontal sync pulse must be present to be considered valid.
To trigger on a specific line of video
Video triggering requires greater than 1/2 division of sync amplitude with 
any analog channel as the trigger source. Turning the trigger Level knob in 
Video trigger does not change the trigger level because the trigger level is 
automatically set to the sync pulse tips.